C-5400 - Synthetic Fiber Sheets with Neoprene Binder

Technical Sheet

APG's C-5400 - Synthetic Fiber Sheets with Neoprene Binder gasket material is a high-performance premium sheet that is chemically stable and provides excellent sealability in many applications including refrigerants, oils, gas, and fuels.

This material is manufactured with synthetic fibers reinforced with a neoprene binder.

5400b

 

Features & Applications

Features

  • Synthetic Fiber

  • SBR Biner Reinforcement

Applications

  • Petrochemical / Chemical

  • Mining / Steel / Aerospace

  • Transportation / Railcar

  • Paper / Pulp

Product Specifications

Typical Values Refer to 1/16'' Thick Material Unless Noted

Creep relaxation ASTM F38B (1/32") 25 %
Sealability ASTM F37 A (1 /32") < 0.2 ml/hr
Gas Permeability DIN 3535/6 < 0.5 ml/min
Compressibility ASTM F36J 7 - 15 %
Recovery ASTM F36J 50 % minimum
KLINGER Hot Compression Test  
1 Thickness Decrease 73°F (23°C) 1 13 % initial
2 Thickness Decrease 392° F (200°C) 2 23 % additional
Weight increase ASTM F146 after immersion in  
Fuel B, 5h/73°F (23°C)
15 % maximum
Thickness Increase ASTM F146 after immersion in  
1 ASTM Oil IRM 901, 5h/300°F (149°C)  1 0 - 5 % 
2 ASTM Oil IRM 903, 5h/300°F (149°C) 2 5 - 20 %
3 ASTM Fuel A, 5h/73°F (23°C) 3 0 - 5 %
4 ASTM Fuel B, 5h/73°F (23°C) 4 0 - 10 %
Dielectric Strength ASTM 0149-95a 18 kV/mm
Density ASTM F1315 106 lb/ft ³ (1.7 g/cc ³)
Leachable Chloride Content FSA Method 500 ppm
ASTM F104 Line Call Out F712232B3E22K6M5
Color Black or White

 

DOWNLOAD SPEC SHEET

Pressure/Temperature Graphs

The pressure/temperature graphs shown are the most current method of determining the suitability of a gasket material in a known environment. However, chemical compatibility must also be considered.

pT diagram for thickness 1/16":

Gases & Steam

C-5400 G&S

Liquids

C-5400 liquids

In area 1 the gasket material is suitable using common installment practices subject to chemical compatibility.

In area 2 appropriate measures are necessary for installation of the gasket to ensure maximum performance.

In area 3 do not install gaskets in these applications without first contacting APG for technical support service.