APG C-4201 - Compressed Non-Asbestos Sheets with Nitrile Binder

Technical Sheet

APG's C-4201 - Compressed Non-Asbestos Sheets with Nitrile Binder is a general application gasket material that offers excellent resistance to oils and solvents and is an excellent choice for OEM applications.

This compressed fiber gasket material is manufactured with a combination of synthetic fibers reinforced with a nitrile binder.

4201w

 

Performance & Applications

Performance Applications
  • Max Temperature: 450°F

  • Continuous Max with Steam: 375°F

  • Oils & Solvents

  • Chemical Products

  • Water

  • Low Temperature Steam

    Product Specifications

    Typical Values Refer to 1/16'' Thick Material Unless Noted

    Creep relaxation ASTM F38B (1/32") 20 %
    Sealability ASTM F37A (1/32") < 0.5 ml/hr
    Gas Permeability DIN 3535/6 < 0.5 ml/min
    Compressibility ASTM F36J 7 - 17 %
    Recovery ASTM F36J 50 %
    KLINGER Hot Compression Test  
    1 Thickness Decrease 73°F (23°C) 1 16 % initial
    2 Thickness Decrease 572° F (300°C) 2 20.5 % additional
    Weight increase ASTM F146 after immersion in  
    Fuel B, 5h/73°F (23°C) 10 % maximum
    Thickness Increase ASTM F146 after immersion in  
    1 ASTM Oil IRM 901, 5h/300°F (149°C)  1 0 - 5 % 
    2 ASTM Oil IRM 903, 5h/300°F (149°C)  2 0 - 5 % 
    3 ASTM Fuel A, 5h/73°F (23°C)  3 0 - 5 % 
    4 ASTM Fuel B, 5h/73°F (23°C) 4 0 - 5 %
    Dielectric Strength ASTM D149-95a 14 kV/mm
    Density ASTM F1315 119 lb/ft ³ (1.9 g/cc ³)
    Leachable Chloride Content FSA Method 200 ppm
    ASTM F104 Line Call Out F712121B3E11K6M5
    Color Black or White

     

    DOWNLOAD SPEC SHEET

    Pressure/Temperature Graphs

    The pressure/temperature graphs shown are the most current method of determining the suitability of a gasket material in a known environment. However, chemical compatibility must also be considered.

    pT diagram for thickness 1/16�:

    Gases & Steam

    4201-gases

    Liquids

    4201-liquid 2

    In area 1 the gasket material is suitable using common installment practices subject to chemical compatibility

    In area 2 appropriate measures are necessary for installation of the gasket to ensure maximum performance.

    In area 3 do not install gaskets in these applications without first contacting APG for technical support service.